AbelBonded
GC Columns
AbelBonded® GC Columns: High performance, low bleed, high inertness, and reproducibility. Suitable for diverse sample matrices with strict quality control and competitive pricing.

Features
.png)
Highlights
- Complete stationary phase selections: Polysiloxane, Polyethylene glycol (PEG) and PLOTs;Complete stationary phase selections: Polysiloxane, Polyethylene glycol (PEG) and PLOTs;
- Available in many dimensions (variations in length, internal diameter and film thickness);
- Consistent High performance: lowest bleed, the highest inertness, high efficiency, the most consistent retention time and the greatest repeatability;
- A wide variety of sample matrices, such as food, environmental, clinical toxicology, petrochemical, flavours and fragrances standard mix....
- Competitive price.
.jpg)
Silica Monolith packing material
New separation media that are neither particulate nor membrane
Silica monoliths are integral silica gels with uniform continuous pores synthesized from ethyl silicate. They have high liquid permeability and large surface area possessing a structure with through-pores and mesopores on the framework surface. This state-of-the-art media is becoming popular globally for its characteristics: high recovery and high performance of adsorption and desorption.

Advantages to conventional particle type packing
- Disk-shaped silica monoliths do not use frits to hold particle media
- The massive surface area of monolithic material makes it possible makes it possible to retain samples in the cartridge and completely elute small samples during processing allowing for much smaller volumes of sample needed.
- Despite high liquid permeability, silica monoliths are still suitable for rapid elution without the loss of high recovery with fast sample diffusion and quick separation.
Products
Available Formats for Spin Columns

S Type spin column
- Disk size: 4.2 O.D. x 1.5 mm
- Sample volume: 50-800 µL
- Elution volume: 50-800 µL
- Centrifugation speed: 2,000-10,000 x g

L Type large volume reservoir spin column
- Disk size: 9 O.D. × 3 mm
- Sample volume: 0.5-8 mL
- Elution volume: 0.5-8 mL
- Centrifugation speed: 1,000 x g

96-well plate
- Disk size: 4.2 O.D × 1.5 mm
- Sample volume:~800 µL
- Elution volume: 100-800 µL
- Centrifugation speed: 2,000-10,000 x g (centrifuge; can also be used in vacuum aspiration)
Available Functional Groups for Spin Columns
| Product | Functional Group | S/96 well Through pore (µm) | S/96 well Mesopore (nm) | L Type Through pore (µm) | L Type Mesopore (nm) | Surface Area (m²/g) | Bed Capacity (for type S) |
| MonoSpin C18 | Octadecyl group | 5 | 10 | 10 | 10 | 350 | 100 µg (amitriptyline) |
| MonoSpin C18 FF | Octadecyl group | 20 | 15 | 10 | 10 | 300 | 50 µg (amitriptyline) |
| MonoSpin Ph | Phenyl group | 5 | 10 | - | - | 350 | 100 µg (amitriptyline) |
| MonoSpin C18-AX | Octadecyl group, Quaternary ammonium | 5 | 10 | - | - | 350 | 100 µg (ibuprofen) |
| MonoSpin C18-CX | Octadecyl group, Benzenesulfonic acid group | 5 | 10 | - | - | 350 | 100 µg (amitriptyline) |
| MonoSpin SAX | Trimethylaminopropyl group | 5 | 10 | 10 | 10 | 350 | 100 µg (ibuprofen) |
| MonoSpin SCX | Propylbenzenesulfonic acid group | 5 | 10 | 10 | 10 | 350 | 100 µg (amitriptyline) |
| MonoSpin NH2 | Aminopropyl group | 5 | 10 | 10 | 10 | 350 | 100 µg (maltopentaose) |
| MonoSpin CBA | Carboxyl group | 5 | 10 | 10 | 10 | 350 | 100 µg (amitriptyline) |
| MonoSpin Amide | Amide group | 5 | 10 | - | - | 350 | 100 µg (angiotensin II) |
| MonoSpin PBA | Phenylboronic acids | 5 | 10 | - | - | 350 | 100 µg (dopamine) |
| MonoSpin TiO | Titanium dioxide | 20 | 15 | - | - | 350 | 40 µg (adenosine monophosphate) |
| MonoSpin Trypsin | Trypsin | 5 | 10 | - | - | 350 | - |
| MonoSpin ME | Iminodiacetic acid group | 5 | 10 | 10 | 10 | 350 | 25 µg (Cu ions) |
| MonoSpin Phospholipid | Titanium dioxide, Zirconium dioxide | 5 | 10 | 10 | 10 | 350 | 10 µL (human serum) |
| MonoSpin ProA | Protein A | 2 | 60 | - | - | - | 400 µg (human IgG) |
| MonoSpin ProG | Protein G | 2 | 60 | - | - | - | 400 µg (human IgG) |
How to choose Functional Groups
The MonoSpin series are optimized as a spin-column for pretreatment of biological samples. If you are working on highly viscous samples such as blood, MonoSpin C18 FF is the best choice. Please refer to the following chart for choosing appropriate MonoSpin:


How To Operate
Short time centrifugation is used to pass the liquid in solid-phase extraction. The entire sample treatment process can be completed within 10 minutes.


Watch Video
How to use MonoSpin: a spin column for concentration and purification of trace level samples
Applications
Performance in analysis of trace analytes
Due to its high permeability, MonoSpin series enables collection of trace analytes without the need for dilution.
S type Column

L type Column

Find reference analyses from our list of available applications for MonoSpin.

Get Expert Advice or a Personalized Quote
Connect with a GL Sciences specialist today. Send us your questions, and our team will provide the expertise you need to help you find the right MonoSpin spin column.
Send us a message now, or: